เครื่องหมุนเหวี่ยงสำหรับการทดสอบกรดนิวคลีอิกของ Coronavirus COVID-19

เวลา: 2022-01-24 จำนวนครั้งที่เข้าชม: 137

As the outbreak pneumonia that caused by coronavirus COVID-19 has spread across continents, more and more people begin to worry that the epidemic would upgrade into a pandemic. Scientists and doctors are working together internationally to study further about this new coronavirus and trying to develop the vaccine as soon as possible.

For laboratory diagnosis, centrifuge is one of the essential equipments in laboratory nucleic acid testing of coronavirus COVID-19. As a manufacturer and enterprise of lab centrifuge, we have the responsibility to give our efforts to fight against this disease. Currently we have 3 models suitable for the clinical and diagnostic laboratory.

Model 1: TGL-20MB
เครื่องหมุนเหวี่ยงแช่เย็นความเร็วสูง
Max. Speed: 20000r/min
แม็กซ์ RCF: 27800xg
Max. Capacity: 4x100ml
Temperature range: -20oC to 40 oC,
Accuracy: ±2 oC
Timer range: 1min~99min59sec
Motor: Converter motor
เสียงรบกวน: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 18A
น้ำหนักสุทธิ: 70kg
ขนาด: 620x500x350mm (LxWxH)

1-1

โรเตอร์:
Angle Rotor 24x1.5ml, 16000rpm, 23800xg
With aerosol-tight lid

图片 16

Model 2: XZ-20T
เครื่องหมุนเหวี่ยงความเร็วสูง
Max. Speed: 20000r/min
แม็กซ์ RCF: 27800xg
Max. Capacity: 4x100ml
Timer range: 1min~99min59sec
Motor: Converter motor
เสียงรบกวน: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 5A
น้ำหนักสุทธิ: 27kg
ขนาด: 390x300x320mm (LxWxH)

1-3

โรเตอร์:
Angle Rotor 24x1.5ml, 16000rpm, 23800xg
With aerosol-tight lid

未标题-6

Model 3:  TD5B
เครื่องหมุนเหวี่ยงความเร็วต่ำ
Max. Speed: 5000r/min  
แม็กซ์ RCF: 4760xg
Max. Capacity: 4x250ml
Timer range: 1min~99min59sec
Motor: Converter motor
เสียงรบกวน: <55db
Screen: LCD color screen
Acceleration / Deceleration rates: 1--10
Power: AC220V, 50/60Hz, 5A
น้ำหนักสุทธิ: 35kg
ขนาด: 570x460x360mm (LxWxH)

1-7

โรเตอร์:
Swing Rotor 48x 5ml, 4000rpm, 2980xg
including a (stainless steal) rotor arm and 4 (aluminum alloy) rectangular buckets
For blood collection tubes (vacutainers) 5ml(13x100mm)
With aerosol-tight lid

1-8

1-9


Swing Rotor 48x 2ml, 4000rpm, 2625xg
including a (stainless steal) rotor arm and 4 (aluminum alloy) rectangular buckets
For blood collection tubes (vacutainers) 2ml(13x75mm)
With aerosol-tight lid

1-10

1-11

The above 3 models and rotors are more needed than often due to the increasingly huge needs from laboratory diagnosis on coronavirus COVID-19. Xiangzhi company is trying the best to ensure the production and supply for these models. And on the order hand we consider the biosafety as prior thing for lab workers, we highly appreciate the advices and suggestions of improving our centrifuge designs that’s able to protect lab workers better.

Lastly, please be aware of the following points when handling with hazard hazardous Material in laboratory:
Working in clinical diagnostic laboratories usually means working with potentially infectious samples like blood or other bodily fluids. But handling infectious microorganisms or harmful chemicals is quite common in research laboratories as well. To ensure the safety of laboratory personnel and to prevent laboratory acquired infections (LAIs) or other health hazards, reasonable precautions must be taken throughout the whole workflow.

เครื่องหมุนเหวี่ยงเป็นแหล่งหนึ่งของละอองลอย กิจกรรมต่างๆ มากมาย รวมถึงการเติมหลอดสำหรับการหมุนเหวี่ยง การถอดฝาหรือฝาปิดออกจากหลอดหลังจากการปั่นแยก และการกำจัดของเหลวเหนือตะกอนออก จากนั้นจึงนำเม็ดที่แขวนลอยกลับคืนมา สามารถนำไปสู่การปล่อยละอองลอยออกสู่สภาพแวดล้อมของห้องปฏิบัติการได้
Thus, aerosol-tight lid or biocontainment cover is essential for centrifuging hazardous samples, such as blood collection tubes (vacutainers)

Aerosol-tight lids do not prevent formation of aerosols during centrifugation; rather, they ensure aerosols cannot leak from the closed system.
หากท่อแตกหรือรั่ว ห้ามเปิดเครื่องหมุนเหวี่ยงเป็นเวลาอย่างน้อย 30 นาทีหลังการทำงาน เนื่องจากไม่สามารถตรวจพบสิ่งนี้ได้เสมอไปก่อนที่คุณจะเปิดถังหรือโรเตอร์ (ความไม่สมดุลอย่างกะทันหันอาจเป็นสัญญาณแรกของการแตกหักของท่อ) เราขอแนะนำให้รออย่างน้อย 10 นาทีตลอดเวลาก่อนที่จะเปิดภาชนะ
นอกจากนี้ คุณควรโหลดและขนถังหรือโรเตอร์ลงในตู้ความปลอดภัยทางชีวภาพ (โดยเฉพาะอย่างยิ่งในด้านไวรัสวิทยาและมัยโคแบคทีเรีย) เพื่อลดความเสี่ยงในการหลุดพ้นจากละอองลอยให้เหลือน้อยที่สุด